During the discharge of a lead-acid battery, the overall reaction is: . What happens to the concentration of sulfuric acid during discharge?
- AIt decreases because is consumed as a reactantCorrect
- BIt increases because releases sulfate ions
- CIt remains constant because the reaction is at equilibrium
- DIt increases because water is formed
Why A is right
During discharge, sulfuric acid is consumed as a reactant (appearing on the left side of the equation). Two moles of are used for each unit of reaction, forming . The sulfate ions () are incorporated into the insoluble lead sulfate precipitate on the electrodes, reducing the acid concentration in solution.
Why the other 3 choices miss
- B
- Incorrect. is an insoluble solid that forms on the electrodes. It does not release sulfate ions () back into solution during discharge.
- C
- Incorrect. During discharge, the reaction proceeds in the forward direction (spontaneous), consuming . The system is not at equilibrium during operation.
- D
- Incorrect. While water () is formed, this does not increase concentration. In fact, water formation dilutes the remaining acid further.