On this page · 5 sections
AP Chemistry hands you numbers before it hands you a question. Section I is 60 multiple-choice questions in 90 minutes, and many of them arrive in sets of two to four items hanging off one stimulus: a titration curve, an initial-rates table, a photoelectron spectrum, a heating curve, a box of drawn particles. Section II is 7 free-response questions in 105 minutes, 3 long and 4 short, and the long ones almost always open with a data table or a plot. You get a periodic table and an equations sheet for both sections. You get a calculator only on Section II.
The task is always the same underneath: a graph or table encodes one relationship, and you have to name that relationship and pull a number or a conclusion out of it. Multiple-choice scoring is blunt. One point, right or wrong, no guessing penalty, so never leave a data item blank.
Free-response scoring is where reading skill turns into points. Rubrics are analytic: one point for the correct value with correct units, a separate point for a justification that names the specific feature of the data you used. Saying the rate went up earns nothing. Saying that the plot of ln[A] against time is linear, so the reaction is first order in A, earns the point. Describing what a graph looks like is not analysis. Connecting a feature of the graph to a chemical rule is.
The steps
- 1
Read the axes before you look at the curve
Spend the first five seconds on the labels, not the shape. Three things decide everything that follows. What quantity is on each axis, what units it carries, and whether the axis is a transformed variable. AP loves plotting ln[A], 1/[A], ln k, or 1/T rather than the raw quantity, and a line on one of those axes means something completely different from a line on raw axes. Check whether the origin is actually on the graph, because an axis that starts at 0.20 M makes a gentle trend look dramatic. Count the value of one gridline. Note the exponent printed on the axis, since a y-axis reading 2.0 with a header of times ten to the negative third is 0.0020, not 2.
- 2
Name the archetype
AP Chemistry reuses a short menu of plots. Each one encodes exactly one thing. Learn the menu and you know what a slope or a flat stretch will mean before you read a single value.
- Photoelectron spectrum: how many electrons sit at each binding energy. - Mass spectrum: isotope abundances. - Titration curve: moles of titrant, and the strength of the analyte. - Linearized kinetics plot, ln[A] or 1/[A] against t: reaction order. - Energy profile: activation energies and enthalpy change. - Maxwell-Boltzmann curve: the fraction of molecules above the activation energy. - Heating curve: phase changes and heat capacities. - Beer's law calibration line: concentration from absorbance. - Pressure against 1/volume, fixed sample: the slope is nRT. - Pressure against temperature, fixed volume: the slope is nR/V. Different quantities from the plot above. Run this line backwards and its x-intercept lands near -273 degrees Celsius, absolute zero. - Vapor pressure against temperature: boiling points and intermolecular force strength. - Concentration against time that levels off: an equilibrium position and the reaction stoichiometry. - Particulate diagram, a box of drawn spheres: relative amounts, never absolute ones. Before-and-after boxes give limiting reactant and leftover excess. A single box gives relative concentrations at equilibrium, or how particles pack in a solid, liquid or gas. - Table of standard reduction potentials: which species gets reduced, and how much voltage the cell delivers.
Identify which one you are holding before you read a single value. Once you have named it, you already know what the axes, slopes and flat regions are going to mean.
- 3
Go to the landmarks, not the overall shape
Every archetype has two or three privileged points, and the question is almost always about one of them. A titration curve has three. The initial pH gives Ka for a weak acid through an ICE setup. The steepest point is the equivalence point. For a weak acid titrated with strong base, the pH at half the equivalence volume equals the pKa; on a strong acid with strong base curve that same half-volume pH carries no pKa information at all. On a heating curve the landmarks are the plateaus, where temperature holds still while a phase changes, and the slopes, where only temperature changes. On an energy profile they are the peaks, which are transition states, and the wells between them, which are intermediates. On a photoelectron spectrum they are peak positions and peak heights. On a linearized kinetics plot the slope gives the rate constant, or negative Ea over R on an Arrhenius plot. Watch the intercepts, because they do not all mean the same thing. The y-intercept of a ln[A] or 1/[A] plot is the starting concentration in that same transformed form. The y-intercept of an Arrhenius plot is ln A, the frequency factor, and has nothing to do with concentration. On a pressure against 1/volume line the landmark is the slope. On a pressure against Celsius temperature line it is the x-intercept, which extrapolates to about -273 degrees. On a vapor pressure curve it is where the curve crosses 760 torr, the normal boiling point. On a concentration against time plot it is where the curves flatten, which is equilibrium.
Landmarks are where most numerical answers come from, but the stretches between them carry chemistry the exam asks about. The region between the start of a weak-acid titration and its equivalence point is the buffer region, and pH creeps rather than jumps there because appreciable amounts of both HA and A- are in solution. On a heating curve, the relative lengths of the two plateaus and the relative steepness of the sloped segments are themselves comparison questions.
- 4
Convert one landmark into a number with units
Landmarks are only worth points once they become quantities. Slope of ln[A] against t is negative k, so k equals the absolute slope in reciprocal seconds. Slope of 1/[A] against t is k directly, in reciprocal molarity per second. Slope of [A] against t is negative k, in molarity per second. Slope of ln k against 1/T is negative Ea divided by R. The intercepts of those same plots give the starting value: ln[A]0, 1/[A]0, or [A]0. On an Arrhenius plot the intercept is ln A instead.
Volume at equivalence times titrant molarity gives moles of titrant delivered, not moles of analyte. Multiply by the analyte-to-titrant mole ratio from the balanced neutralization equation. The two are equal only for a 1:1 reaction, such as a monoprotic acid with NaOH. Neutralizing H2SO4 with NaOH takes two moles of NaOH per mole of acid, so moles of acid are half the moles of titrant there.
Peak height on a photoelectron spectrum is proportional to the electron count in that subshell, but the vertical axis is only relative intensity. So anchor the scale to a peak whose occupancy you already know. The far-left 1s peak is always 2 electrons. Divide every height by the 1s height, then multiply by 2, and the peaks become electron counts. Sodium comes out 2:2:6:1, which sums to 11. Do not divide by the smallest peak. That shortcut only works when some subshell holds exactly one electron, as sodium's 3s does. Run it on magnesium, 1s2 2s2 2p6 3s2, and the true 2:2:6:2 collapses to 1:1:3:1, summing to 6 instead of 12.
Absorbance divided by calibration slope gives concentration, as long as the calibration line passes through the origin. AP usually stipulates that it does; if the printed line has a y-intercept, subtract it before you divide. Slope of P against 1/V gives nRT for the sample, in liter-atmospheres. Cell potential equals the cathode reduction potential minus the anode reduction potential, and you never scale a potential by the coefficient used to balance electrons. Current in amperes times time in seconds divided by 96,485 gives moles of electrons; divide by the electrons per ion, then multiply by molar mass, for grams of metal deposited. Write the unit as you write the number, because the unit of a rate constant is itself evidence of the order.
- 5
For tables, change one variable at a time
Data tables are designed for a controlled comparison, so find the two rows where exactly one thing differs. In a method of initial rates table, pick two trials with the same [B] and different [A]. Divide the rates and divide the concentrations. If tripling [A] triples the rate, the order in A is 1. If tripling [A] multiplies the rate by 9, the order is 2. If nothing changes, the order is 0. Never compare rows where two concentrations moved. In a successive ionization energy table, look for the one enormous jump; the number of ionizations before that jump equals the valence electron count, which fixes the group. In calorimetry data, identify which substance lost heat and which gained it before you touch a formula.
Two more table types work differently. Given a set of concentrations and a K value, put the numbers into the equilibrium expression to get Q, then compare. Q below K means the reaction runs forward toward products, Q above K means it runs backward toward reactants, and Q equal to K means no net shift. In a table of standard reduction potentials, the half-reaction with the more positive value happens as printed and is the cathode; the other one reverses, becomes the oxidation, and is the anode.
- 6
Sanity-check sign and magnitude
Two seconds of checking catches most data errors. Rate constants and equilibrium constants are never negative, but which slope carries the minus sign depends on the axes. Slope is negative k for [A] against t and for ln[A] against t, so take the magnitude on those. Slope is positive k for 1/[A] against t, and negative Ea over R for ln k against 1/T. A negative slope on a 1/[A] plot, or a positive slope on ln k against 1/T, means you misread or swapped the axes; it is not a sign to strip off. An exothermic process has negative enthalpy change and its energy profile ends lower than it started. A weak acid titrated with strong base has an equivalence pH above 7, because the conjugate base left in solution is basic. A pKa read off a curve should land between about 2 and 11; a pKa of 40 means you misread the axis. Half-life for a first-order reaction must be the same on every interval. Gas and thermodynamic temperatures are in kelvins, so a negative absolute temperature means you forgot to add 273. A galvanic cell that runs on its own has a positive cell potential. If your calculated concentration exceeds the range of your calibration curve, you extrapolated past the data and should say so.
- 7
Write the justification as feature, rule, conclusion
Free-response points live in a three-part sentence. Name the specific feature of the data, state the rule it triggers, then give the conclusion. The plot of 1/[A] against time is linear, and only a second-order reaction linearizes on those axes, so the reaction is second order in A. The pH at the half-equivalence volume of 12.5 mL is 4.7, and at half-equivalence pH equals pKa, so Ka is about 2 times ten to the negative fifth. Quote the actual number you read off the graph. A justification that never mentions a value from the stimulus reads as a memorized fact and usually earns nothing, even when the conclusion is correct.
Worked through
Example 1: kinetics data with no plot.
A student measures the decomposition of a reactant A at constant temperature and records concentration against time.
t (s): 0, 100, 200, 300, 400 [A] (M): 0.400, 0.283, 0.200, 0.141, 0.100
Step 1, read the axes. Raw concentration in molarity against time in seconds. No transformation yet, so a curve here tells you nothing about order by itself.
Step 2, name the archetype. This is a kinetics data set, so the question is order and rate constant, and the tool is linearization.
Step 3, test the three orders by differences instead of plotting. Zero order needs [A] to fall by equal amounts each interval. The drops are 0.117, 0.083, 0.059 and 0.041 M. They shrink, so it is not zero order. First order needs ln[A] to fall by equal amounts. The values are -0.916, -1.262, -1.609, -1.959 and -2.303, dropping by about 0.346 each interval. That is constant, so first order. Confirm by checking 1/[A]: 2.50, 3.53, 5.00, 7.09, 10.0. The increments are 1.03, then 1.47, then 2.09, then 2.91. They accelerate instead of holding steady, so it is not second order.
Step 4, get k with units. Use the endpoints, not neighboring points, so rounding error is spread out. Slope equals (-2.303 minus -0.916) divided by 400 s, which is -1.387/400, or -3.47 times ten to the negative third per second. For a first-order plot the slope is negative k, so k equals 3.5 times ten to the negative third s to the minus one. The unit of reciprocal seconds is itself a check that the order is 1. The y-intercept of that same plot would be ln(0.400), or -0.916, which recovers the starting concentration.
Step 5, cross-check with half-life. Concentration goes 0.400 to 0.200 in 200 s, then 0.200 to 0.100 in the next 200 s. A constant half-life is the signature of first order. And 0.693 divided by 200 s gives 3.47 times ten to the negative third per second, matching the slope.
Step 6, write the justification. The plot of ln[A] against time is linear with slope -3.47 times ten to the negative third per second. Only a first-order reaction gives a straight line on those axes. So the rate law is rate equals k[A], with k of 3.5 times ten to the negative third per second. If the next part doubles the starting concentration, the initial rate doubles but the half-life stays at 200 s, because first-order half-life does not depend on concentration.
Example 2: a titration curve read.
A 25.0 mL sample of an unknown monoprotic acid is titrated with 0.100 M NaOH. The curve starts at pH 2.65, rises slowly, jumps almost vertically at 20.0 mL, and levels off high.
Find the landmarks first. The steep jump at 20.0 mL is the equivalence point. Half of that is 10.0 mL, and the curve reads pH 4.20 there.
Moles of titrant at equivalence: 0.0200 L times 0.100 M equals 2.00 times ten to the negative third mol NaOH. Now apply stoichiometry. The acid is monoprotic, so the balanced reaction is 1:1 and moles of acid also equal 2.00 times ten to the negative third. Concentration is that divided by 0.0250 L, or 0.0800 M. If the same curve came from a diprotic acid titrated to its second equivalence point, the ratio would be 1 mol acid per 2 mol NaOH, and the answer would be 1.00 times ten to the negative third mol, half as much.
Get Ka. This is a weak acid with a strong base, so pH at half-equivalence equals pKa. pKa is 4.20, so Ka is ten to the negative 4.20, about 6.3 times ten to the negative fifth.
Cross-check that Ka against the starting pH, because the curve gives you the same quantity twice. Run an ICE setup on 0.0800 M acid. [H+] is the square root of Ka times the initial concentration, which is the square root of 6.3 times ten to the negative fifth times 0.0800. That is 2.2 times ten to the negative third M, so pH 2.65. It matches the printed starting point, so the half-equivalence reading was not a misread gridline.
Sanity-check the rest. A pKa of 4.20 is in the plausible 2 to 11 window. The acid is weak, so the equivalence pH must sit above 7, and the curve should show the jump centered near pH 8.4. The stretch from about 2 mL to about 18 mL is the buffer region, where pH climbs slowly because HA and A- coexist there.
Justification sentence: the pH at 10.0 mL, half the 20.0 mL equivalence volume, is 4.20, and at half-equivalence [HA] equals [A-] so pH equals pKa, giving Ka of 6.3 times ten to the negative fifth.
Common mistakes
Judging order from the shape of a raw [A] versus time curve. Both first- and second-order decays curve downward and flatten out, and they look nearly identical over a short window. Only the linearized plot, or equal-interval differences in ln[A] and 1/[A], separates them.
Assuming the equivalence point of any titration sits at pH 7. That is true only for strong acid with strong base. A weak acid titrated with strong base equivalates above 7, and a weak base with strong acid below 7. The equivalence point is the steepest part of the jump, not the pH-7 crossing.
Reading the half-equivalence point as half the total volume of titrant added, or half the x-axis. It is half the volume required to reach equivalence. Find the equivalence volume first, halve that, and read the pH there. For a weak acid titrated with strong base that pH is the pKa. For a weak base titrated with strong acid, the pOH at half-equivalence is the pKb, and the pH is the pKa of the conjugate acid. Any weak analyte works. A strong acid with strong base curve is the one that carries no pKa information anywhere on it.
Reporting moles of titrant at equivalence as moles of analyte. Those match only when the balanced neutralization is 1:1, and the direction of the ratio matters. H2SO4 with NaOH takes 2 mol of base per mole of acid. A monoprotic acid with Ba(OH)2 takes 2 mol of acid per mole of base. H2SO4 with Ba(OH)2 is back to 1:1, because the diprotic acid and the dihydroxide base cancel. Read the ratio off the balanced equation every time instead of assuming a factor of 2; guessing it doubles or halves your answer.
Misreading a photoelectron spectrum by treating peak height as energy or peak position as electron count. Position on the binding-energy axis tells you which subshell; height tells you how many electrons occupy it. Also check the axis direction, since binding energy is usually printed increasing to the left.
Adding raw peak heights on a photoelectron spectrum to get Z, or scaling every peak against the smallest one. The intensity axis is relative, so anchor it to a peak of known size instead. The 1s peak is always 2 electrons. Divide by its height, multiply by 2, and sodium reads 2:2:6:1, summing to 11. The smallest-peak trick works on sodium only by luck, and breaks on neon, whose true 2:2:6 comes out 1:1:3 and sums to 5 instead of 10.
Counting the spheres in a particulate diagram as moles and reading the leftovers straight off. The boxes show relative amounts, not absolute ones, and you still have to divide each count by that species' coefficient in the balanced equation. The reactant with the smaller quotient is limiting. What remains in the after box is the excess left once that ratio is applied, not the raw difference between the two counts.
Applying q = mc(delta T) across a plateau on a heating curve. Temperature is constant during a phase change, so that expression gives zero. Plateaus need moles times the enthalpy of fusion or vaporization; only the sloped segments use mass, specific heat and temperature change.
Comparing two rows of an initial-rates table in which more than one concentration changed, then attributing the whole rate change to one reactant. Find rows where the other concentrations are held fixed, or divide out the known order before solving for the unknown one.
Putting Celsius into a gas relationship. Pressure against temperature is a straight line through the origin only in kelvins. Heating from 20 to 40 degrees Celsius is 293 K to 313 K, a 7 percent rise, not a doubling.
Reading the flat part of a concentration versus time plot as the concentrations becoming equal. Flat means the forward and reverse rates are equal. The plateau values are usually different from each other, and they go straight into the equilibrium expression as read.
Multiplying a standard reduction potential by the coefficient used to balance electrons. Potential is intensive, so doubling a half-reaction leaves its voltage unchanged. Only the free energy change scales with moles of electrons.
Checklist
- Can you look at a plot for five seconds and say what is on each axis, in what units, and whether the variable is transformed?
- Can you decide reaction order from a table of concentration and time without plotting anything, using equal-interval differences in [A], ln[A] and 1/[A]?
- Can you state the units of a zero-, first- and second-order rate constant, and use those units backwards to identify an order?
- Can you say what the y-intercept means on a ln[A] versus t plot, a 1/[A] versus t plot, and an Arrhenius plot, and explain why the Arrhenius one is ln A rather than a concentration?
- Can you locate the equivalence point, the half-equivalence point and the buffer region on a weak-acid titration curve, and get pKa from the right one?
- Can you get moles of analyte from an equivalence volume when the acid is diprotic, and point to where the factor of 2 comes from?
- Can you read activation energy forward, activation energy reverse, enthalpy change, intermediates and transition states off one energy profile?
- Can you identify an element from a photoelectron spectrum by scaling every peak against the 1s peak's 2 electrons, and explain what a peak's position means?
- Can you use a before-and-after particulate diagram to name the limiting reactant and count what is left over, dividing each species by its balanced coefficient first?
- Can you split a heating curve into segments and choose q = mc(delta T) or q = n(delta H) correctly for each one?
- Can you get nRT from the slope of a P against 1/V line, and explain why P against Celsius temperature extrapolates back to about -273 degrees?
- Can you compute Q from a table of concentrations, compare it with K, and say which direction the reaction shifts?
- Can you pick anode and cathode from a standard reduction potential table, compute the cell potential, and turn amperes and seconds into grams of metal plated?
- Can you write a justification that names a specific number from the stimulus, states the rule it triggers, and reaches the conclusion in one sentence?